Skip to content

Home / Key Products / Railways and MetroHVAC Unit (Passenger Coach)

Specifications

  • No. of circuits: Two
  • Refrigerant: R 407C
  • Airflow: 4000 m3/hr
  • Power consumption: 16.5 kVA
  • Enclosure: Stainless steel SS 304
  • Power supply: 415V AC/3 phase/50 Hz
  • Cooling capacity: 7 Ton/24.6 kW at 50°C ambient
  • Fresh air damper (louvers) control: Manual/Motorized
  • Control & safety sensors: Temperature, pressure, humidity, heater OHP (two stage)
  • Heating capacity: 6.0 kW/9.0 kW heating element with option of reverse cycle heating
  • Control parameters: Automatic control through microprocessor based controller
  • Compressor: Hermetically sealed scroll with option of VVVF driven inverter compressor

Certification(s)

ISO 22163 (IRIS) AS 9100
ISO 9001 ISO 14001
ISO 45001 ISO 13485

Compliant Standard(s)

IEC 60571 IEC 61373
IEC 60529 EN 45545-2
IEC 61000-4-2, 3, 4, 5 IEC 60068-2-1, 2, 14, 30